Example 1 Two PLATES OF 130×8( GRADE 300W) ARE CONNECTED TOGETHER USING M16 BOLTS IN PUNCHED HOLES AND THE EDGES OF THE PLATES ARE GAS-CUT. ( 1 ) check the spacing configuration. ( 2 ) Determine the tensile Resistance. PITCH IS 60mm EDGE IS 35mm END IS 35mm Steps to follow: Calculate ; i). Spacing configuration ii). Modes of failure in Bolt Connections iii). Bolt shear v). Bolt bearing Notes : fu = 450Mpa for 300W fu = 480Mpa for 350W m is Number of shear planes : 1 for single shear plane 2 for double shear plane